231 characters in length. A message cannot though, contain an @S
command in combination with any other command. A message
also should not contain more than 1 request for data entry (third
character in command is 1). For example:
@1,1,1,ITEM@2,1,1,QTY
has two data entry “prompt” commands combined. If this message
were sent to the RF Terminal, the first data entry prompt
(@1,1,1,ITEM) would be executed, but any and all commands after
the first data entry prompt in that statement would be ignored
without warning – there will be no display or indication of an illegal
command.
The @S command (for serial output) statement cannot be
combined with any other command - even clear (@Cx) commands.
After a @S command is successfully completed, the Base Station
sends back to the host the RF Terminal ID followed by a CR
(ASCII 13). There is a 231 character limit on data for this
command. If you send a command of more than 231 characters,
you will get an Illegal Command returned, (ID ? CR). If you need
to send 300 characters of data, send the first part, wait for the
acknowledgement (ID CR), and then send the remaining part. If
you are using the @S command with a printer other than the Zebra
Cameo or QL3, you may have to change the Protocol parameter in
the RF Terminal to XON/XOFF. This will allow the RF Terminal
to deal with the character buffer limitations of your particular
printer. If you are using the O’Neil MicroFlash Printer, you must
send a NULL character before the valid data to wake up the
printer. See your printer manual for details and see Chapter 6 for
details on printer protocol.
The @M command is similar to the @S command, except it can
be combined with other commands because it is a data entry
command too. This command is for a printer initialization and
magstripe input on the Zebra Cameo printer equipped with the
magstripe option. The format of the command is:
@Mdddatttta(EOT)
where dddatttta might be ! U1 MCR 80 T1 T2+ CR + LF
(Refer to the Cameo manual for the exact string sequence you need
to send. The above example sends over an 10 second request for
reading Track 1 and Track 2).
There is no reply to the host except the magstripe data. If the card
cannot be read, pressing the ENTER key on the Terminal will send
back ID+CR. This is the breakout method.